2026/11/26 ENABLE GAS TRANSMISSION, LLC PAGE: 1
MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020
TIME: 15:01:174
Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane %
O2 C1 C2 C3 C5 C6 C7 C8 C9
----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ----------
BAY CHECK GC @ 170610 2026/11/25 0.5828 1.02313 0.9756 00.6399 00.0000 00.0000 95.3031 02.9074 00.1535 00.0064 00.0088 00.0000 00.0015 00.0010 00.0011 00.0008 00.0004 00.0000
CUSTER ST @ LINE AD ST1 2026/11/25 0.5760 1.01376 0.4958 01.2898 00.0000 00.0000 95.9968 02.1485 00.0659 00.0014 00.0015 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000
GLENDALE CEGT TO MRT @ 2026/11/25 0.5898 1.03377 0.7345 01.0284 00.0000 00.0000 93.5871 04.4684 00.1599 00.0057 00.0082 00.0000 00.0016 00.0012 00.0021 00.0015 00.0007 00.0000
CHANDLER ST DISCHARGE G 2026/11/25 0.5871 1.03049 0.7084 01.0141 00.0000 00.0000 94.1127 03.9683 00.1784 00.0064 00.0070 00.0000 00.0014 00.0011 00.0008 00.0006 00.0003 00.0000
FM 63 - Columbia GC @ 2 2026/11/25 0.6046 1.08067 0.2021 00.4197 00.0000 00.0000 90.3653 08.6353 00.3158 00.0214 00.0275 00.0000 00.0055 00.0033 00.0016 00.0012 00.0006 00.0000
The information displayed above reflects daily average gas quality readings
taken at key locations on the EGT system. The dates shown above are the
dates of the readings. The readings are taken daily, and information from such
readings is posted on the first day thereafter. If on any reading day there
are problems retrieving the data, the last reported readings will remain
posted until such time as new readings are obtained. Due to factors such as
equipment failure, sample contamination and human error, the information
displayed above may not be completely accurate.